Roland XY Série Mode D'emploi page 33

Table des Matières

Publicité

Liste des instructions
en RD-GL II
* 1: - ( 2
23
)—( 2
23
-1)
23
* 2: - 0— + ( 2
-1)
* 3: - ( 23 )°—+ ( 2
23
-1)°
15
15
* 4: - ( 2
)— + ( 2
-1)
Instruc- Compati-
Format
tion
bility
AA
AA x,y,øc(,ød);
AF
AF;
AH
AH;
AP
AP n;
AP;
AR ∆x,∆y,øc(,ød);
AR
BL
BL c1c2...cn
[label terminator]
BL [label terminator]
CA
CA n;
CA;
CC
CC øc;
CC;
CI
CI r(,ød)
CM
CM n1(,n2);
CP
CP nx,ny ;
CP ;
CS
CS n;
CS;
CT
CT n;
CT;
DC
DC;
DF
DF;
DI
DI run,rise;
DI;
DL
DL n(,pc),x1,y1.....
(,pc).....,xn,yn;
DL n;
DL;
DP
DP;
DR
DR run,rise;
DR;
DS
DS s,n;
DS;
30
Cette liste indique la compatibilité du langage RD-
GL II avec le DXY-1350A/1150A et les paramètres
pour chaque instruction.
Parameter
Range
x,y: Center
: *1
coordinate
øc: Center angle
: *3
ød: Chord tolerance
: *3 [5°]
None
None
n: Pen control value
0-225 (Decimal fractions are rounded.)
∆x,∆y: Relative
: *1
coordinates to the center
øc: Center angle
: *3
ød: Chord tolerance
: *3 [5°]
cn: Character
n: Character set
: -1,0-59,70,80,99,101
number
øc: Center angle
: *3 [5°]
r: Radius
: *1
ød: Chord tolerance
: *3 [5°]
n1: Character set
0-3
mode
(Decimal fractions are rounded) [0]
n2: Fall back mode
: 0 or 1
(Decimal fractions are rounded) [0]
nx: The number of X-
: *1 (Decimal fractions are rounded)
axis directional characters
ny: The number of Y-
: *1 (Decimal fractions are rounded)
axis directional characters
n: Character set
: -1,0—59,70,80,99,101
number
n: Chord tolerance
: 0 or 1
mode
(Decimal fractions are rounded) [0]
None
None
run: X-axis
: *1 [1]
directional vector
rise: Y-axis
: *1 [0]
directional vector
n: Character number
: 33—126 (Decimal fractions are rounded)
pc: Pen control
: -128 (Decimal fractions are rounded)
xn,yn: Grid
: -127—+127 (Decimal fractions are rounded)
coordinate values
none
run: X-axis
: *1 [1]
directional vector
rise: Y-axis
: *1 [0]
directional vector
s: Slot number
: 0—1 (RD mode)
0—3 (ISO mode)
(Decimal fractions are rounded) [0]
n: Character set
: -1,0—60,70,80,99
number
(Decimal fractions are rounded)
: Compatible.
: Ignorée.
: Incompatible.
([ ]: Default)
The maximum character buffer capacity, including control
characters (e.g., label terminator) is 150 characters. Characters
more than 150 are ignored.
•Any character number without the range of *1 results in error
(3). If a character number is within that range, it results in error
(5) and the instruction is ignored.
The maximum center angle is 45°. This means that even if
specifying a center angle more than 45°, 45° will be set.
If any pen moving distance exceeds 8388607 and also any pen
movement to any coordinates exceeding *1, it results in error (3)
and the instructions are ignored.
Any character number without the range of *1 results in error (3).
If a character number is within that range, it results in error (5)
and the instruction is ignored.
Expanation

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dxy-1350aDxy-1150a

Table des Matières