Connections; Connecting To The Rs-485; Connecting Hd-Sdi Output Connector; Connecting Alarms - Eneo HDD-2030PTZ1080 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connections

Connecting to the RS-485

The dome camera can be controlled remotely by an external device or control system,
such as a control keyboard, using RS-485 half-duplex serial communications signals.

Connecting HD-SDI Output connector

Connect the HD-SDI output (BNC) connector to the monitor or video input.

Connecting Alarms

A1,A2,A3,A4 (Alarm Input 1,2,3,4)
You can use external devices to signal the dome camera to react on events. Mechanical or
electrical switches can be wired to the A1,A2,A3,A4 (Alarm Input 1,2,3,4) and G (Ground)
connectors.
See Program and Operation for configuring alarm input.
G (Ground)
NOTICE: All the connectors marked G or GND are common.
i
Connect the ground side of the alarm input and/or alarm output to the G (Ground)
connector.
AO1,AO2 (5VTTL Alarm Output 1,2)
The dome camera can activate external devices such as buzzers or lights. Connect the
device to the AO1,AO2 (Alarm Output 1,2) and G (Ground) connectors.
See Program and Operation for configuring alarm output.

Connecting the Power

Connect power of 12VDC or 24VAC for the dome camera.
When using a 12VDC adapter, connect the positive (+) pole to the '+' position and the
negative (-) pole to the '-' position.
20

Publicité

Table des Matières
loading

Table des Matières