Power Supply Connections - Eneo IPB-73M2812MWA Guide Rapide

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Adjustment of viewing angle with a bracket
Lock / Unlock
screw
Torque wrench

Power supply connections

Make sure the power is removed before the installation. Camera can work with either
24VAC or 12VDC, dual voltage power and PoE (IEEE Std. 802.3af ). Primary and secondary
grounds are completely isolated to avoid the possible ground loop problems.
1. Plug the network cable into RJ-45 Ethernet Port. If PoE is the unique power, there
will be no need to connect Power terminal.
2. When DC12V or AC24V Local power is necessary, connect the low voltage (DC12V
from power jitter and a damage from the surge voltage when no load.
i
When PoE and local dual power are connected at the same time, local power has
priority.
Attach the Signal Assignment Sticker in a visible spot for wiring reference.
10
AC24V/DC12V (Red wire)
AC24V/GND (Black wire)
Alarm-IN (Green wire)
Alarm-OUT (Blue wire)
GND (Gray wire)
Audio-IN (Brown wire)
GND (Gray wire)
Audio-OUT (Orange wire)

Publicité

Table des Matières
loading

Table des Matières