Combustion air slide valve

 Operating lever on „0":
all slide valves closed
 Operating lever on „I":
Secondary air slide valve completely open /
Primary air slide valve completely closed
 Operating lever on „II":
Secondary air slide valve completely open /
Primary air slide valve completely open

Regulation of combustion air

Position of operating lever:
„II" ..... Ignition position, max. heat output
„I"....... Nominal heat output with billet wood
„I"....... Nominal heat output with wood briquettes
„0" ..... Obtain glow
 As the secondary air also contributes to the
cleanliness of the glass pane, the operating lever
should be set on "I" minimum. This also applies in the
event of low-load operation.
 When not operating the lever should be set on"0", to
reduce the cooling down of the room.
24

Fire grate

 With the help of the operating lever the fire grate can
be opened or closed to move the ash from the
combustion chamber to the ash pan by pushing the
fire grate back and forth.
 Primary air can only enter the combustion chamber if
the fire grate is set on open position.