Failed Ignition; Setting Operating Temperature And Power; Operating Phases Of The Appliance; Sequence Of Ignition Phases - Ravelli Touch Radio Manuel D'utilisation Et D'entretien

Portable
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48

Failed ignition

If the system does not detect the ignition of the flame within the preset time, operation will be blocked with the "No ignition" alarm.
Before relighting the stove, check that there are pellets in the hopper, that the door and ash drawer compartment are closed, that there
are no obstructions to the combustion air inlet system and above all that, in models without self-cleaning brazier, the brazier is empty,
clean and correctly positioned. If the problem persists, it could be due to a technical problem (ignition plug, adjustments, etc ...), so
please contact a Ravelli CAT.
The accumulation of unburned pellets in the brazier after a failed ignition must be removed before proceeding with a new
ignition.
The brazier could be very hot: danger of burns!
Never empty the brazier inside the hopper.

Setting operating temperature and power:

Set the two values following the indications given in the chapter "Description of the display"

OPERATING PHASES OF THE APPLIANCE

Sequence of ignition phases

IGNITION - initial pellet loading phase;
FLAME LIGHT - flame stabilization phase and reduction of combustible inside the brazier;
WORK - operation phase described in the dedicated chapter;

Modulation

During the work phase, the appliance should reach the room temperature set; when this condition is met, the stove switches to MODULATION
mode in which fuel consumption is minimum.
The first setting allows the activation of the CLIMATE COMFORT function. This function is intended to ensure that the room tem
-perature set is maintained steady upon setting the maximum period of "X" minutes (SWITCH-OFF DELA
Y: 5 MIN) before switch-ing to ECO STOP phase. The STOVE maintains this state until the temperature drops below the set
value (CLIMATE COMFORT DELTA : 5 ).
For example, with the room temperature at 21 ° C, the stove switches of f when this temperature is
reached and restarts when the temperature reaches 15°C (21°C - 5°C - 0,5°C tolerance).
You can also activate the function using an external thermostat, keeping in mind that this does not include the value of the hyster
-esis.
��
If you wish to detect the ambient temperature by means of an external thermostat (optional), this must be connected to
We recommend you use an external thermostat with a histeresys value that can be set to maximum 3°C.
the appropriate connector on the rear side of the stove; and you will have to activate the reading in "SETTINGS - ENABLE
The operation of the stove could activate the switch ON/OFF phases for several times during the day;
THERMOSTAT." On display appears the writing TON / TOFF based on thermostat request.
this may affect the service life of the ignition coil.
Connect an external thermostat with a simple dry contact, therefore, not powered, moreover, we recommend you use a
USING THIS METHOD, IT IS NECESSARY TO VERIFY THAT AFTER EACH AUTOMATIC SHUTDOWN
thermostat with a minimum offset of 3°C if you ntend to use the comfort clima function.
THE GRATE IS ALWAYS VERY CLEAN TO GUARANTEE CORRECT AUTOMATIC SWITCH ON.
AUTOMATIC SWITCH ON.

Description of menu functions

Description of menu functions
Press the key to access the MENU page
Press the key to access the MENU page
��
The TECHNICIAN and MANUFACTURER menus are protected by password.
The TECHNICIAN and PRODUCER menus are password protected. Changing parameters within these menus could
compromise the operation and safety of the stove. In this case the warranty will be invalidated.
Chronothermostat
With the Chrono-thermostat function you can program the automatic switch ON/OFF of the stove for each day of the week
for each day of the week in 4 independent time intervals (SET CHRONO 1-2-3-4)
Use and maintenance manual Phandheld Touch Radio
User's manual HANDHELD TOUCH RADIO
MENU
MANUFACTURER
TECHNICIAN
ENGINEER
PRODUCER
MENU
USER
USER
Rev.0 17/05/2021
EN
Pag.25
Vers. 01 of:07.04.14
Pag.24

Publicité

Table des Matières
loading

Produits Connexes pour Ravelli Touch Radio

Table des Matières