ELECTRICAL CONNECTION

Preliminary controls
Before connecting the machine to a socket, take care:
Make sure the socket is provided with a ground protection
-
Make sure that the voltage and frequency of supply correspond to those indicated on
-
the data plate of the machine
Make sure about the way on how to connect the power cable to avoid the possibility of
-
sliding and tripping
It is user responsibility that the connection of the machine to the electric system is in
-
compliance with the rules in force in the country where the machine is installed, and it
has been made by a qualified technician.
Once all preliminary controls have been correctly done, use the main power switch to
-
start your machine
USE OF THE MACHINE
This machine is equipped with an innovative technology suitable to reach high performances with energy saving (up to 50% less compared to other
machines with same performances).
The electronic card supplies the welding bar with the correct power, changing automatically the welding time, depending on the network voltage; the seal
control is a balance between electronic (automatic) and user (manual) setting.
Once connected, the machine is ready for use by pressing the main power switch (11) if present. Correct
vacuum packaging extends food storage time.
The appliance is intended to be used with Reber embossed bags of the same type as furnished with the machine, if used with different or other
label bags the machine may not have same performances.
This appliance is not intended for use with high grade humidity food; liquids suction may damage the appliance (pump, el. card and vacuum
chamber gasket) and this is considered inappropriate use and out of warranty cover.
Correct storage:
Bags and appliance must be stored in a dry and no dust place with temperature between +10° to +30°.
VACUUM PACKAGING IN BAGS AUTOMATIC
USE
-
Prepare the food which is to be vacuum preserved taking off every thorns or spikes could pierce the bag, in an embossed bag of adequate size,
leaving about 5 cm from the edge of the bag and the food.
-
Lift the cover up (4).
-
Place the open side of vacuum bag in the vacuum chamber (6), between the gaskets (5). Image 1 - Close the cover and press pump switch (1).
This will start vacuum operation.
-
As soon as vacuum pump starting, slightly press with both hands the cover so as it sticks to the surface of the bag. After a few seconds the
depression created by the pump will permit to release the cover, while the machine will keep on suction.
-
Seal will start automatically and the machine will automatically stop at the end of the cycle.
USER INTERVENTION
-
Every operation will stop when pressing pump switch (1).
-
It is possible to start sealing cycle when a correct vacuum level is attended (between the two black lines on green space of the manometer), by
pressing welding switch (2). Low vacuum level could affect welding efficiency, if cover (4) doesn't exert a minimum power on the welding
bar.
-
BE CAREFUL: pressing the welding switch (2) after the start of automatic welding will end welding operation.
USE OF ROLLS - welding without vacuum
-
Lift the cover (4) and place the roll (in well spread conditions) on the welding bar. Make sure that the open side of the roll is NOT inside the
vacuum chamber (6). Image 2
-
Start the air pump by pressing switch (1). Slightly press your hands on the cover (6) to close the vacuum chamber.
-
When the vacuum level is reached, welding starts automatically. -
VACUUM PACKAGING IN CONTAINER
(containers provided with vacuum valve are required for this operation; only containers suitable for vacuum packaging, in plastic material or toughened
glass, shall be used).
-
Set on Manual cycle.
-
Lift the cover.
-
Introduce the adapter hose into the air suction plugs.
-
Fill the container leaving at least 3 cm. free room from the upper rim and place the cover on it.
-
Slightly unscrew the cover cap to unlock the valve (attention: the cap must not be unscrewed completely, some turns are enough).
-
Place the adapter for containers on the cap.
-
Start up the air pump by pressing switch (1) and wait for the desired vacuum level.
-
Press switch (1) to stop the machine, remove the adapter for containers from the container cover and screw the cap to lock the valve. -
To open the container, slightly unscrew the cap to unlock the valve; then move the valve to let air into the container.
After welding the unit stops. Cut the roll and use like a bag.