Technical Characteristics; Applied Standards - REBER 9714 N Notice D'utilisation Et Entretien

Machines a sous-vide pro
Masquer les pouces Voir aussi pour 9714 N:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1
If you have not waited for the minimum time prescribed between connection to
-
2
network and cycle starting, act as follows: unplug, plug again and wait as long as
required.
When containers are used particular attention should be paid to welding bar heating
-
(7.) to prevent burns.
For safety reasons, we recommend to operate manually when containers are used
-
and the vacuum gauge pointer (3.) reaches the limit of the yellow area.
Check the supply cord periodically, if damaged replace it with a supply cord of the
-
same type as the one provided; its replacement must be done by qualified technician
in order to avoid a hazard
The appliance is protected by a fuse placed in a tray under the connection socket of
-
the machine; in case of problem, a spare fuse is placed in the same tray. Take off the
tray and change the fuse. The fuse is not cover by warranty.
"Only for U.S.A. use" To reduce risks of electric shock, this product has a polarized plug
(one blade is wider than the other). This plug is intended to fit in a polarized outlet only one
way. When the plug does not fit fully in the outlet, reverse the plug. When it still does not fit,
contact a qualified electrician to install the proper outlet.

TECHNICAL CHARACTERISTICS

Code
Model
Body
Pump
Max. Power Absorbed
Max vacuum level
Aspiration
Outlet for canister attachment
Vacuometer
Potentiometer
Filter for EMC
Fuse 6A
Spare Fuse 6A
Code
Liquids Protection Filter
Code
Model
Body
Pump
Max. Power Absorbed
Max vacuum level
Aspiration
Outlet for canister attachment
Vacuometer
Potentiometer
Filter for EMC
Fuse 6A
Spare Fuse 6A
Led
Liquids Protection Filter
Legend
1.
Start cycle switch
2.
Seal Switch
3.
Vacuum gauge
4.
Cover
5.
Vacuum Chamber Gasket
6.
Vacuum chamber

APPLIED STANDARDS

Refer to the Declaration at the end of this document
9714 N - NEL
Professional 40
Stainless Steel
Twin cilinder Energy saving
345 W
-900 mbar
40 lt/min
YES
YES
YES – NO on NEL
YES
YES
YES
9714 NF
YES
9709 NE
Professional 30 Eco
Inox
One cilinder Energy saving
200 W
-850 mbar
18 lt/min
YES
YES
NO
YES
YES
YES
2
NO
Packaging contains: 20 Bags cm. 20x30, Canisters attachment
9716 N - NEL
EcoPro 40
Stainless Steel
Twin cilinder Energy saving
335 W
-900 mbar
40 lt/min
YES
YES
YES – NO on NEL
YES
YES
YES
9709 N – NEL - NELF
Professional 30
Inox
Twin cilinder Energy saving
280 W
-900 mbar
40 lt/min
YES
YES
YES - NOT ON NEL
YES
YES
YES
1 - 2 ON NEL
YES only on NELF
7. Welding bar
8. Air outlet
9. Potentiometer / LED on models NE - NEL
10. Welding bar gasket
11. Main power switch
12. Led
9712 N - NEL
Professional 55
Stainless Steel
Twin cilinder Energy saving
355 W
-900 mbar
40 lt/min
YES
YES
YES – NO on NEL
YES
YES
YES
9712 NF
YES
9709 NF
Professional 30 with filter
Inox
Twin cilinder Energy saving
280 W
-900 mbar
40 lt/min
YES
YES
YES
YES
YES
YES
1
YES

Publicité

Table des Matières
loading