Clearances To Non-Combustible Walls; Floor Protection - RAIS Topas Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

US English
User Manual RAIS Topas & RAIS Opus
Clearance to non-combustible wall
We recommend a minimum clearance to non-combustible material of at least 2" (50 mm) so
that cleaning is easy. The cleaning door should be accessible at all times.
Clearances may only be reduced by means approved by the regulatory authority.

Floor protection

Floor protection must be non-combustible material extending beneath the stove, and to the
front and sides from door opening and to rear as indicated.
Floor protection for Canada: 18" (45 cm) from unit to front of floor protector.
Floor protector must be under connector pipe an 2" (5 cm) to the side for a thru-the wall
configuration.