Problem
Atomisation too
coarse
Spray jet pulsates
Coating material
causes "paint tears"
Too much fog of
coating material
(Overspray)
Paint in the
ventilating hose
Poor covering
capacity on the wall

19. Technical Data

Max. viscosity
Power source
Power consumption
Atomizing output
Max. flow rate
Double insulation
Sound pressure level*
12
Cause
Viscosity of coating material too
high
Material volume too large
Material volume adjusting screw
turned too far to the right (+)
Nozzle contaminated
Air filter heavily soiled
Too little pressure build-up in
container
Coating material in container
running out
Air filter heavily soiled
Nozzle seal is missing or worn
Too much coating material
applied.
Distance to the object too large
Too much coating material
applied
Diaphragm soiled
Diaphragm defective
Spray material is too cold
Highly absorbent surface or paint
with poor covering capacity
Distance too large
Technical Data
2700 mPas
230 V, ~ 50 Hz
320 W
80 W
230 ml/min
76 dB (A); Uncertainty K = 3 dB
HV2501EU
Remedy
➞ Thin
➞ Turn material volume
adjusting screw to the
left (-)
➞ Clean
➞ Change
➞ Tighten container
➞ Refill
➞ Change
➞ Insert an intact nozzle
seal
➞ Turn material volume
adjusting screw to the
left (-)
➞ Reduce distance
➞ Turn material volume
adjusting screw to the
left (-)
➞ Clean the diaphragm
➞ Replace the diaphragm
➞ The material you are
spraying should be at
room temperature
➞ Cross spray (Fig. 8)
➞ Closer to the object