TESTING AND ADJUSTMENTS

Initial Setup
The TEST mode overrides the photocell (daylight shutoff
feature) and allows the light fixture to be tested day or night
when the ON-TIME switch is in the TEST position. The
light will stay on for 5 seconds after all motion has stopped.
TEST 1 5 10
MINUTE
Sensor Controls
1. Turn the DualBrite control to OFF.
2. Set the ON-TIME control to TEST.
3. Turn on the circuit breaker or fuse and the light switch.
4. Allow the sensor to completely warm up (90 seconds)
before beginning the setup process.
5. Perform a walk test. Walk in an arc across the front of
the sensor.
6 ft .
(1 .8 m)
30 ft . (9 .1 m)
Maximum Range
206546-02
OFF
3 6
DUSK TO
HOUR
DAWN
150°
Maximum
Coverage Angle
(Top View)
7
6. Move the sensor head left or right to change the coverage
area. Note: Grasp the sensor only as shown and turn
the entire sensor. Any other method may damage
the sensor. Do not force it past the stops.
Rotating Sensor Head to Change Coverage Area
Final Setup
1. Adjust the sensitivity (SENS) to increase or decrease
the range as needed. Too much sensitivity may cause
false triggering due to heat sources in the coverage area
(see Testing and Adjustments or Troubleshooting section).
2. Set the amount of ON-TIME you want the light to
stay on after motion is detected (1, 5, or 10 minutes).
3. Set the DualBrite® switch to off, 3 hours, 6 hours,
or dusk-to-dawn.
4. Caulk around fixture base with silicone weather seal-
ant after all Testing and Adjustments are complete.
Caulking Around Fixture Base