Forch Powerwash Bio Mode D'emploi page 61

Masquer les pouces Voir aussi pour Powerwash Bio:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 66
7 DIAGNOSIS
The pump and the heating resistor are not functioning. The red indicator light flashes. Causes:
The liquid level has reached its minimum. Add liquid.
The green indicator light is off => the heating has not been switched on, the pump does not function:
The immersion function is used, the immersion basin is closed.
The liquid level is too low for immersion. Add liquid and switch on heating.
The immersion function is not used and max. liquid level in the immersion basin is reached.
The basket filter is clogged. Clean filter and then switch on heating.
No flow of fluid at the brush
Take the brush holder off the quick connector. Does the liquid pour out of the brush holder?
If yes: the brush is clogged
If no: Pump malfunction
8 NOTEPAD
Rated Operating Temperature: The operating temperature of 38°C varies by +/- 1°C. BOOST-
temperature: Rated operating temperature + 5°, limited to 45°C.
ECO- temperature: 29°C/30°C.
INDICATOR LIGHT HEATING
The indicator light is off: The heating function is switched off.
The indicator light flashes normally: The temperature of the degreasing bath is rising.
The indicator light flashes pulsed (0,1s on / 2,5s off): Rated operating temperature of
the degreasing bath is maintained.
FILLING LEVEL
The red indicator light is off: The degreasing bath contains enough liquid.
The red indicator light flashes: The liquid has reached the minimum level. Add liquid.
2h00
The green indicator light flashes.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

5378 8

Table des Matières