(4) Wire between indoor and outdoor units.
Single-phase unit: GUD35W/NhA-T, GUD50W/NhA-T, GUD71W/NhA-T,
GUD85W/NhA-T.
breaker
PE
Power:220-240V~50Hz/208-230V~60Hz
breaker
PE
Power:220-240V~50Hz/208-230V~60Hz
GUD35P/A-T+GUD35W/NhA-T, GUD35PS/A-T+GUD35W/NhA-T
GUD50P/A-T+GUD50W/NhA-T, GUD50PS/A-T+GUD50W/NhA-T
①.
Power cord 3×1.5mm²
②.
Power cord 3×1.0mm²
③.
Communication Cords 2×0.75mm
④.
Communication Cords 2×0.75mm
GUD71P/A-T+GUD71W/NhA-T, GUD71PS/A-T+GUD71W/NhA-T
GUD85P/A-T+GUD85W/NhA-T, GUD85PS/A-T+GUD85W/NhA-T
①.
Power cord 3×2.5mm²
②.
Power cord 3×1.0mm²
③.
Communication Cords 2×0.75mm²
④.
Communication Cords 2×0.75mm²
Outdoor Unit
L N
L1 N1
L N
Outdoor Unit
L N
L1N1
L N
DC Inverter U-match Series Duct Type Unit
Indoor Unit
Wired
Controller
breaker
Power:220-240V~50Hz/208-230V~60Hz
Indoor Unit
Wired
Controller
Power:220-240V~50Hz/208-230V~60Hz