4 Mounting
The camera can be installed on a camera stand, on a
pan / tilt head (e. g. MONACOR VPT-50), or on a camera
support (e. g. support of the MONACOR TVH series). For
mounting, the lower side of the camera is provided with an
adapter (10) with thread jack [6.3 mm (
suspension of the camera, this adapter can alternatively
be screwed to the upper side of the camera.
For outside installation, the camera must be mounted
into a weatherproof outdoor housing.

5 Connecting the Camera

5.1 Video connection

Connect the BNC jack "VIDEO" (11) via a 75 Ω cable (e. g.
MONACOR VEC-62/10) to the video input of the following
unit (e. g. monitor, video recorder). With a cable length
exceeding 100 m, a video amplifier should be inserted be-
tween the camera and the cable to compensate cable loss.
If the following unit is equipped with an S-video input,
instead of the BNC video output, the video output
"S-VIDEO" (12) should be used for video connection. The
signal is available in the S-video format (S-VHS format) at
this output. Since, contrary to the composite colour signal
at the BNC output, the brightness and colour information
is separately transmitted in the S-video signal, the picture
quality will improve with this connection.
5.2 Remote control via the jack "REMOTE"
1
Via the 6-pole jack "REMOTE" (8), the camera can be
/
") thread ]. For
4
remote-controlled: via the optional remote control RMA-
1602 (fig. 2) or alternatively via a computer or control con-
sole by serial data transmission according to RS-485
standard.
1
2
When using the remote control RMA-1602, connect it
to the jack "REMOTE" via its cable. The remote control
does not require any batteries, power is supplied via the
camera.
Pin
RS-485
6
5
1
TxD (A)
2
RxD (B)
3
4
5
3
4
6
Pin configuration of the 6-pole jack "REMOTE"
Remote control RMA-1602
Ground
Power supply +12 V
Control line 1
Control line 2