Installation and any transformation for using other types of gas, must be performed by qualified technicians according
to the law in force.
See technical data tables: 1.1 and 2.5
WARNINGS:
Should the unit be installed against a wall, the latter must be heat resistant to temperatures of 90°C and must be fireproof.
Before proceeding with the installation, remove the protective plastic film from the relevant parts, eliminating any adhesive
residues with an appropriate cleaning product suitable for stainless steel.
Install the unit in a horizontal position; its correct levelling will be achieved by rotating the adjustable feet.
If the unit is installed by itself, it is advisable to fasten it to make its stability safer.
2.1

INFORMATION ABOUT GAS RANGE

This manual applies to our Gas Range, Type A1 Category II (Natural Gas and L.P.G.).
See table 1.1 and 2.5.
The label according to EN437 and EN203
regulations, Part 1, is located:
a) for the units with oven, on the front-
lower panel
b) for the units with no oven, in the cabinet's
low-left side
Example for Italy label: Category II 2H3÷
Pe= Incoming Pressure
Pi= Nozzle Pressure
2.2
LAWS, REGULATIONS AND
TECHNICAL DIRECTIVES TO BE
COMPLIED WITH
The following indications should be observed during installation:
- Accident and fire regulations in force
- Prescriptions by the Gas Supply Company, which should issue an authorisation before installation.
- Instructions for the "Installation of gas equipment"
- Instructions for the "Installation of electrical equipment"
- Prescriptions by the Electrical Supply Company
- Hygienic regulations.
2.3

INSTALLATION PLACE

- The unit should be installed in adequately ventilated places. (This unit requires a draft of at least 2cu.m/hr l kW T.C.
(Thermal Capacity).
- Install the equipment in compliance with the safety rules applicable in the country where the equipment is installed.
2.4

POSITIONING

- The various units may be installed individually or together with other units of our range.
- This unit is not suitable for encasing.
- The distance between side walls must be a minimum of 10cm; should the distance be less or the wall or floor material be
flammable, it is essential to use a thermal insulator.
The gas unit should be installed under a draft hood whose system ought to have characteristics complying with Regulations.
GB

INSTALLATION INSTRUCTIONS

V
IT-GR-GB-ES-IE-PT
IS-MT-CY
Cat.
II2H3+
I3B/P
P n
20,29/37
30/30
PT
NO-SE-EE-LT-DK-LV-CZ-SK-SI-FI-TR-HR-BG-RO
Cat.
II2H3+
II2H3B/P
P n
20,50/67
20,30/30
G20
Qn
KW
(Hi)
G25
- 22 -
Mod.
Matr.N°
Hz
kW
PL
FR - BE
DE
II2E3P
II2E+3+
II2ELL3B/P
20/37
20/25,29/37
20,20,50/50
NL
II2L3B/P
25,30,30
G30
m
/h
3
m
/h
G31
3
Type
tipo
LU
I2E; I3+
mbar
20,29/37
AT-CH
II2H3B/P
mbar
20,50/50
Kg/h
Kg/h

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

C6gfa11-sp

Table des Matières