Malfunction
Heavy build up of frost, possi-
bly also on the door seal.
Unusual noises.
The compressor does not start
immediately after changing
the temperature setting.
Water on the floor or on sto-
rage shelves.

Changing the light bulb

Warning! There is a risk of electric shocks! Before changing the light bulb,
switch off the appliance and unplug it, or pull the fuse or the circuit breaker.
Light bulb data: 220-240 V, max. 15 W
1.
To switch off the appliance, turn the temperature regulator to position "0".
2.
Unplug the mains plug.
3.
To change the light bulb, undo the
screw.
4.
Press the light bulb cover as shown
and slide it backwards.
5.
Change the defective light bulb.
6.
Refit the light bulb cover and the
screw.
7.
Put the refrigerator back into opera-
tion.
42
Possible Cause
Door seal is not air tight (pos-
sibly after changing over the
hinges).
Appliance is not level.
The appliance is touching the
wall or other objects.
A component, e.g. a pipe, on
the rear of the appliance is
touching another part of the
appliance or the wall.
This is normal, no error has
occurred.
Water drain hole is blocked.
Remedy
Carefully warm the leaking
sections of the door seal with
a hair dryer (not hotter than
approx. 50 °C). At the same
time shape the warmed door
seal by hand such that it sits
correctly.
Readjust the feet.
Move the appliance slightly.
If necessary, carefully bend
the component out of the
way.
The compressor starts after a
period of time.
See the "Cleaning and Care"
section.