3.4
240V hard wire connection
Loosen the securing screw from the terminal block to remove the cord from the terminal block. REMOVE
A.
2 WIRE JUMPERS IN THE TERMINAL BLOCK.
Add a strain relief and feed the supply wires through the 7/8" (22mm) hole from the terminal block.
B.
Insert White (N) wire from power supply to the designated (N) slots in the terminal block. Secure by
C.
tightening the screws on the (N) slots.
Run black (L1), Red (L2), and Green (G) wires from the power supply to designated slots on the terminal
D.
block.
Re-install cover plate.
E.
note:
Leave enough wiring so that the appliance can be removed from the enclosure without disconnecting the
appliance from the power supply.