Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
Kit W175-0636, Natural Gas to Propane Includes;
1
REGULATOR
1
#56 BURNER ORIFICE
1
#35 PILOT ORIFICE (P)
1
CONVERSION DATA LABEL
Kit W175-0635, Natural Gas to Propane Includes;
1
REGULATOR
1
#53 BURNER ORIFICE
1
#35 PILOT ORIFICE (P)
1
CONVERSION DATA LABEL
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a fire, explosion or production of carbon
monoxide may result causing property damage, personal injury or loss of life. The qualified service
agency is responsible for the proper installation of this kit. The installation is not proper and complete
until the operation of the converted appliance is checked as specified in the owner instructions
supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
CAUTION: Before proceeding with conversion shut off gas supply and disconnect electrical power.
1. Lift safety barrier up and out of appliance.
2. Open the glass viewing door and remove the media.
3. Remove the screws securing the log support to the
base. (FIG. 1)
4. Remove the burner and log support.
5. Using a deep socket, remove the main burner orifice.
Use a 7/8" wrench to ensure that the manifold tubing
does not twist or kink. Replace with the orifice supplied.
6. Before replacing the burner assembly, adjust the air
shutter. (See "VENTURI ADJUSTMENT" chart)
7. Replace and re-secure the burner assembly ensuring that
the venturi fits over the burner orifice.
8. To convert the main valve, follow the instructions that are
supplied with the regulator assembly kit. IMPORTANT:
Use the screws provided with regulator.
9. The conversion data label must be filled out and attached
adjacent to the valve.
10. To convert the pilot, remove the clip from the side of the
pilot with pliers. Pull the pilot hood off. Using a 5/32" hex
head Allen key, remove the pilot orifice. Replace the pilot
orifice with the one supplied. Align the pilot hood back to
its original position and place the clip back on the pilot.
(FIG.2)
11. Turn on the gas supply and check for gas leaks by
brushing soap and water solution. Do not use open
flame.
12. Replace the media. Then light the pilot and main burner to ensure that the gas lines have been purged.
13. Re-secure the door. Turn on the electrical supply to the appliance.
14. Reinstall safety barrier.
Purge all gas lines with the glass door open.
Assure that a continuous flow is at the burner before closing the door.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
FUEL CONVERSION KIT FOR MODELS
(C)BL36-1 / (C)BL46
These kits are for use at altitudes of 0 to 4500 feet.
(C)BL36-1
(C)BL46
Kit W175-0637, Propane to Natural Gas Includes;
1
REGULATOR
1
#48 BURNER ORIFICE
1
#62 PILOT ORIFICE (NG)
1
CONVERSION DATA LABEL
Kit W175-0634, Propane to Natural Gas Includes;
1
REGULATOR
1
#43 BURNER ORIFICE
1
#62 PILOT ORIFICE (NG)
1
CONVERSION DATA LABEL
FIG.1
LOG SUPPORT SCREWS
FIG.2
• 1(866)820-8686
(C)BL36-1
(C)BL46
HOOD
PILOT
ORIFICE
CAPUCHON DE
LA VEILLEUSE
INJECTEUR DE
VEILLEUSE
W415-1722 / A / 06.16.17
• www.napoleonfireplaces.com

Publicité

loading

Sommaire des Matières pour Napoleon BL36-1

  • Page 1 Purge all gas lines with the glass door open. INJECTEUR DE Assure that a continuous flow is at the burner before closing the door. VEILLEUSE W415-1722 / A / 06.16.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonfireplaces.com...
  • Page 2 LA FLAMME DOIT (C)BL36-1 (C)BL46 ENVELOPPER LA PARTIE SUPÉRIEURE DE LA SONDE DE FLAMME DE 3/8” (9,5mm) W415-1722 / A / 06.16.17 À 1/2” (12,7mm) Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonfireplaces.com...
  • Page 3 Purgez toutes les conduites de gaz avec la porte vitrée ouverte. Assurez-vous que l’arrivée de gaz au brûleur est continue avant de fermer la porte. W415-1722 / A / 06.16.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonfireplaces.com...
  • Page 4 DE FLAMME DE 3/8” (9,5mm) À 1/2” (12,7mm) Flamme faible (vallée) Flamme grande (pic) Low flame (valley) Tall flame (peak) (C)BL36-1 (C)BL46 W415-1722 / A / 06.16.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonfireplaces.com...

Ce manuel est également adapté pour:

Bl46 cbl36-1Cbl46