INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
(C)A(X)36
Kit W175-0702
Natural Gas to Propane Includes:
1x
Burner
1x
Regulator
1x
#51 Burner orifi ce
1x
Conversion data label
1x
#35 Propane pilot injector
(C)A(X)42
Kit W175-0703
Natural Gas to Propane Includes:
1x
Burner
1x
Air Defl ector
1x
Regulator
1x
#50 Burner orifi ce
1x
Conversion data label
1x
#35 Propane pilot injector
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with
this appliance may result in property damage or personal injury.
CAUTION: Before proceeding with conversion, the gas supply must be shut off prior to disconnecting the electrical power.
1. Remove the safety barrier, door trims, glass door, media, and panels.
2. Remove 11 screws securing the media tray in place. Lift the tray up and out of the
appliance (Fig. 1).
3. Remove 2 screws securing the burner assembly in place then remove 4 screws
securing the air box cover in place (Fig. 2). Llift the assembly up and out of the
appliance to access the orifi ce. Avoid touching nut securing the air shutter slide (Fig.
5).
4. Using a deep socket wrench, remove the orifi ce and replace it with the one supplied.
5. On the burner assembly, remove the screw securing the burner air shutter in place.
Slide the burner from the air box cover hole and discard old burner. Install air box
cover then burner air shutter onto the new burner (supplied) and secure with screw.
Reverse instructions from step 3 to install new burner assembly.
6. a) When converting to natural gas (AX42 only), the front air defl ector must be
removed (Fig. 3).
b) When converting to propane (AX42 only), the front air defl ector must be installed (Fig. 3).
7. Remove the pilot hood from the pilot assembly by unhooking the retaining clip and pulling the pilot hood
vertically. Use a
5
/
" Allen key to unscrew the injector. Replace the pilot injector with the one supplied.
32
Reassemble the pilot hood onto the assembly and reattach retaining clip. Ensure key position for proper
alignment.
8. Remove the 2 screws from the valve regulator and replace with the one supplied (Fig. 4).
9. The conversion data label must be fi lled out and attached adjacent to the valve.
10. Turn on the electriclal supply to the appliance.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada •
FUEL CONVERSION KITS FOR MODEL
(C)A(X)36 / 42
These kits are for use at altitudes of 0 to 4500 feet.
Fig. 2
(C)A(X)36
Kit W175-0711
Propane to Natural Gas Includes:
1x
Burner
1x
Regulator
1x
#33 Burner orifi ce
1x
Conversion data label
1x
#51 Natural gas pilot injector
(C)A(X)42
Kit W175-0712
Propane to Natural Gas Includes:
1x
Burner
1x
Regulator
1x
#32 Burner orifi ce
1x
Conversion data label
1x
#51 Natural gas pilot injector
Fig. 3
1(866)820-8686
Fig. 1
Fig. 4
PILOT
HOOD
PILOT
INJECTOR
SPRING
CLIP
W415-1972 / B / 08.01.19
www.napoleon.com

Publicité

loading

Sommaire des Matières pour Napoleon (C)A(X)36

  • Page 1 9. The conversion data label must be fi lled out and attached adjacent to the valve. 10. Turn on the electriclal supply to the appliance. SPRING CLIP W415-1972 / B / 08.01.19 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 2 Compare them to the illustrations below. BURNER 3/8” - 1/2” (9.5mm - 12.7mm) FLAME SENSOR FLAME MUST ENVELOP UPPER 3/8” (9.5mm) TO 1/2” (12.7mm) OF FLAME SENSOR (C)A(X)36 (C)A(X)42 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 3 L’étiquette de données de conversion doit être remplie et fi xée adjacente à la soupape. PINCE À RESSORT 10. Allumer l’alimentation électrique de l’appareil. W415-1972 / B / 08.01.19 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 4 (9,5mm - 12,7mm) LA SONDE DE FLAMME LA FLAMME DOIT ENVELOPPER LA PARTIE SUPÉRIEURE DE LA SONDE DE FLAMME DE 3/8” (9,5mm) À 1/2” (12,7mm) (C)A(X)36 (C)A(X)42 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...

Ce manuel est également adapté pour:

(c)a(x)42