SOLAR CONTROL PANEL
The.solar.control.panels.adjust.the.circulation.of.the.primary.circuit.with.the.signal.provided.by.the.pump,.according.
to.the.∆t.detected.between.the.solar.collectors.and.the.lower.part.of.the.solar.storage.tank..Depending.on.the.type.of.
installation,.the.control.panels.also.control.the.integration.of.the.secondary.circuit.
The.TERMOSOLIS.control.panel.is.provided.as.per.standard.with.the.GI hydraulic unit.
TERMOSOLIS CONTROL PANEL
TERMOSOLIS.is.a.digital.electronic.device.which.can.be.programmed.to.manage.thermal.solar.plants.
The.solution.manages.wholly.the.solar.system.by.checking.the.pumps,.the.eventual.diverter.valve,.the.probes.(PT1000.e.
NTC),.a.puffer/boiler.and,.also,.another.secondary.heating.source..
The.integrated.user.interface.is.composed.by.a.backlight.display.and.4.buttons..The.display.shows.the.scheme.of.the.
selected.plant.and.the.probes.in.place.with.their.values.and.the.eventual.anomalies,.while.the.buttons.can.switch.on.or.
off.the.device.and.program.the.board.functions..
To.assure.the.system.endurance,.when.switched.off,.some.functions.are.kept.on,.as.the.anti-freezing.protection,.the.
anti-lock.of.the.pump.and.of.the.diverter.valve.
There.are.3.possible.profile.of.the.device,.such.as.Stand.Alone,.in.which.only.TermoSolis.is.present.itself;.communicat-
ing.with.a.Sime.Home/Sime.Home.Plus.remote.control,.so.a.remote.control.and.Full.System.manage.the.system;.and.
then.the.complete.solution,.which.sees.the.connections.with.other.Sime.devices.to.get.the.whole.control.of.the.heating.
and.DHW.plant.
TECHNICAL DATA
Power supply
Frequency
Range of working temperatures
Fuse
Varistor
SOLAR PUMP - P1 TRIAC (230 Vac)
AUX 3 out - P1 PWM (230 Vac)
AUX 2 out - P2 (230 Vac)
AUX 1 out - Enabled thermostat /P2
FREE CONTACT out - D1 (230 Vac)
Range of correct work of the probes
Temperature in which the probe will indicate a fault
General tolerance on temperatures
(referred only to electronic board)
Range of correct work of the probes
Temperature in which the probe will indicate a fault
General tolerance on temperatures
(referred only to electronic board)
Ambient working temperature
Storage and transport temperature
Max. environment humidity (without any condensing)
Function of the buttons:
SERIGRAPH
DESCRIPTION
ON/OFF
BACK
INCREASE
DECREASE
INFO
44
GENERAL
230 Vac +10% ÷ -15%
50Hz +5% ÷ -5%
-20°C ÷ +60°C
3,15AF (fast) 5x20
300 Vac D7
0,5A – Cosφ 1
230Vac – 0,5A
0,5A – Cosφ 1
0,5A – Cosφ 1
230Vac – 0,5A
TEMPERATURE PROBE NTC
-40°C ÷ +105°C
-5°C>>T>>120°C
±1,5°C
TEMPERATURE PROBE PT1000
-40°C ÷ +250°C
-50°C>T>170°C
±1,5°C
ENVIRONMENTAL CONDITIONS OF USE
-20°C ÷ +60°C
-30°C ÷ +60°C
95% a 40°C
FUNCTION
Turn on or turn off the device
Back to previous menu
Go to next parameters or go to next value
Go to previous parameter or go to previous value
Keep pressed for 1 sec.: Temperature information (S2, S3 - S1,S4)
Keep pressed for 10 sec.: Access to programming menu
DIMENSIONS
108 mm
54 mm
54 mm
The plastic box has protection rating IP20
*130 mm is the wheelbase between the holding hanger, which is set up in the front side of the device
34 mm
48 mm
.