Maintenance operations

Important : Only the operations described in this chapter are authorized. All other operations
must be carried out by personnel approved by Virax.

Replacing the motor brushes

The motor will stop working if one of its brushes is worn. Change both brushes.
Disconnect the machine
Remove the handle with a cross-shaped screwdriver
Open the 2 half parts of the handle with a cross-shaped screwdriver
Remove each brush from its housing:
Replace with new brushes (part no. 753291), replace both half parts of the handle and
the complete handle