Troubleshooting
Problem
Pump lacks pressure
Pressure gauge indicates
fluctuations
Noise
Loss of water at head
Loss of oil
Motor fails to start
Motor whines but does
not start up
09.11.2001 8:09 Uhr
Cause
- Unsuitable or worn nozzle
- System is drawing in air
- Worn or dirty valves
- Worn or dirty valves
- Water temperature too high
- Worn seals
- Worn nozzle
- Water temperature too high
- System is drawing in air
- Dirty or worn valve
- Worn sealing rings
- Worn oil sealing rings
- No electricity
- Incorrect mains voltage (less than
-
the prescribed minimum)
- The voltage has been reduced by
-
an extension cable that has the
-
wrong cross-section or is too long
Seite 15
Remedy
- Replace nozzle
- Check intake pipes and seal
- Replace or clean valves
- Replace or clean valves
- Reduce intake temperature
- Replace seals
- Replace nozzle
- Reduce water temperature
- Check pipes
- Clean or replace valve
- Replace sealing rings
- Replace sealing rings
- Check whether the plug is
-
properly inserted in the socket
-
and whether the cable is live
- Check whether the switch
-
is working
- Check power supply
-
for suitability
- Follow the instructions for
-
the use of extension cables
GB