R-410A - General Info - Carrier AquaSnap 30RB Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

:
+7 (495) 545-41-99 (
8-800-555-03-91 (
E-mail: info@i-klimata.ru
www.i-klimata.ru
Contents

R-410A - General info . .............................................................

Safety procedures. ...................................................................
Installation . .................................................................................
Dimensions and clearances . ................................................
Safety procedures - Servicing and maintenance . ........
Technical data ............................................................................
Water connections . .................................................................
Electronic Control . ...................................................................
Electrical connections ............................................................
Auxiliary accessories connection . ....................................
Unit circuit diagram . ..............................................................
Maintenance . ............................................................................
Diagnostic . ..................................................................................
Troubleshooting, guide for the owner and accessories . . ...
Service instructions . ..............................................................
R-410A - General info
This air conditioner adopts HFC refrigerant (R410A) which
does not destroy ozone layer.
R-410A refrigerant operates at high pressures. Be sure
that servicing equipment and replacement components
are designed to operate with R-410A.
R-410A refrigerant cylinders have a dip tube which allows
liquid to flow out with the cylinder in a vertical position
with the valve at the top.
R-410A systems should be charged with liquid
refrigerant. Use a commercial type metering device in the
manifold hose in order to vaporize the liquid refrigerant
before it enters in the unit.
As for other HFC, R-410A refrigerant is only compatible
with oils recommended by the compressor manufacturer.
A vacuum pump is not enough to remove moisture from oil.
Oils absorb moisture rapidly. Do not expose oil to atmosphere.
Use this unit only for factory approved applications.
The capacity and unit code are stated on the nameplate data.
2
30RB
)
)
Page
Air Cooled liquid chillers
INSTALLATION
2
3
4
POSITION THE UNIT
5
5
5
6
WATER CONNECTIONS
9
9
11
12
CONTROL WIRING (Optional)
12
13
14
ELECTRICAL CONNECTIONS
15
FLUSH WATER AND AIR
CHECK FOR WATER LEAKS
CONFIGURE AND CHECK THE SYSTEM
CAUTION:
MODELS WITH HYDRONIC
MODULE
30RB008-9
30RB012-9
30RB015-9
POWER WIRING
FILL THE SYSTEM
MODELS WITHOUT
HYDRONIC MODULE
30RB008X9
30RB012X9
30RB015X9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

30rb008-930rb0012-930rb0015-930rb008x930rb0012x930rb0015x9

Table des Matières