Error Indication - Gree GMV-H224WL/A-X Manuel D'utilisateur

Table des Matières

Publicité

DC Inverter Multi VRF System
(2) Following circumstances are not malfunctions.
Unit doesn't run.
Mist comes from
the unit.
Noise is emitted.
Unit
blows
out
dust.
Unit emits odor.

7 Error Indication

Inquiry method of error indication: combine division symbol and content symbol to check the
corresponding error.
For example, division symbol L and content symbol 4 together means over-current protection.
Error Code
Indoor
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
Malfunction
Unit starts up immediately after it is
turned off.
Power is just turned on.
Under cooling
Slight cracking sound is heard when unit
is just turned on.
There
is consecutive
sound
cooling.
There is sound when unit starts or stops.
There is slight and consecutive sound
when unit is running or after running.
Cracking sound is heard when unit is
running or after running.
Unit starts up after not operating for a
long time.
Under operation
Content
L0
Malfunction of IDU (uniform)
L2
Auxiliary heating protection
L4
Over-current protection
L6
Mode shock
L8
Power supply is insufficient
1-to-more: IDU series is
LA
inconsistent
Models for IDU and ODU are
LC
not matched
d1
Indoor PCB is poor
Malfunction of entry-tube
d4
temperature sensor
Malfunction of exit-tube
d6
temperature sensor
d9
Malfunction of jumper cap
PCB of wired controller is
dH
abnormal
Malfunction of air-outlet
dL
temperature sensor(Fresh air
unit)
FP
Malfunction of DC motor
High pressure ratio protection
J8
of system
Protection due to abnormal
JA
pressure
Overload protection switch makes it run after a
3-min delay.
Standby operation lasts for about 1min.
Indoor air with high humidity is cooled rapidly.
It is the noise when electronic expansion valve is
initialized.
when
It is the sound for gas refrigerant flowing in the
unit.
It is the sound when gas refrigerant stops
flowing.
This is the sound of drainage operation.
This is the sound caused by the expansion of
panel and other parts of the unit due to
temperature change.
Dust in indoor unit is blown out.
Unit absorbs the room odor and then blows it
out.
Error Code
L1
Protection of indoor fan
L3
Water-full protection
L5
Freeze prevention protection
L7
No main IDU
1-to-more: number of IDU is
L9
inconsistent
Alarm due to bad air quality
LH
(Fresh air unit)
Drop protection of discharge
EC
temperature sensor of
compressor 1
Malfunction of ambient
d3
temperature sensor
Malfunction of middle temperature
d5
sensor
d7
Malfunction of humidity sensor
dA
Web address of IDU is abnormal
Abnormal setting for capacity
dC
button
Malfunction of indoor CO
dE
(fresh air unit)
Gas-mixing protection of 4-way
J7
valve
Low pressure ratio protection of
J9
system
JL
High-pressure protection
31
Reason
Content
sensor
2

Publicité

Chapitres

Table des Matières
loading

Table des Matières