Baumer CombiTemp TCR6 Mode D'emploi page 2

Masquer les pouces Voir aussi pour CombiTemp TCR6:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Sensor tube and process connection
Material
Sensor tube diameter
R 1/2 (½" BSPT)
G 1/2 A, G 3/4 A
M18 × 1,5
M20 × 1,5
½-14 NPT
Connection
A
Without
18.5
G 1/2 A, R 1/2
20.5
M18, M20
20.5
½-14 NPT
20,5
G 1/2 A nipple
40,0
G 3/4 A nipple
44,5
G 1 A nipple
47,5
G 1/2 union
51.0
G 3/4 union
51.0
Response time (time constant)
Sensor
Sensor
Insert
diameter
tip
Ø6 mm
Fast
Standard
8 mm
Fast
Standard
Standard
Yes
10 mm
Fast
Standard
Standard
Yes
www.baumer.com
Stainless steel, AISI 316L
Ø6, Ø8 or Ø10 mm
G 1/2 A
G 3/4 A
G 1 A
A/F
L
Ø18
25...3.000
Connection
22.0
25...3.000
G 1/2 A
22.0
25...3.000
22.0
25...3.000
R 1/2
27.0
25...3.000
M18, M20
32.0
25...3.000
½-14 NPT
36.0
25...3.000
G 1/2 A, G 3/4 A,
G 1 A nipple
27.0
25...3.000
G 1/2, G 3/4 union
32.0
25...3.000
0,5
Liquid
Air
0,4 m/sec
3 m/sec
<1,5 sec
<21,4 sec <135,6 sec
<6,1 sec
<27,2 sec <137,8 sec
<1,5 sec
<33,6 sec <181,0 sec
<7,6 sec
<47,7 sec <200,9 sec
<13,6 sec <51,1 sec <253,1 sec
<1,5 sec
<46,8 sec <238,9 sec
<11,1 sec <57,8 sec <270,6 sec
<28,1 sec <67,0 sec <271,1 sec
Operating instructions: 11119033 11
Operating instructions for temperature sensor
TCR6
Industrial temperature sensor
Sensor element specifications (DIN/EN/IEC 60751)
Sensor element
Accuracy (sensor element)
Single element
Double element
Connection
Sensor element
Accuracy (sensor element)
Connection
DIN form B
head
G 1/2
G 3/4
Norm
ISO 228/1
ISO 7/1
ISO 261
ANSI/ASME
ISO 228/1
ISO 228/1
°C
Air
0 m/sec
100
1
80
2
60
40
20
0
1
2
3
Note: When a thermowell is used, the time delay increases.
The delay is the time duration for the sensor to reflect the correct
temperature after a temperature change in the media.
Pt100
Class B
- 1/3 B
- 1/6 B
Class A
1 × Pt100
2 × Pt100
2-wire or 4-wire
Pt1000
Class B ±1/3 × (0,3 + 0,005×t)°C
2-wire
76
71
Sensor tip
Standard
Fast response
3
1: Sensor without thermowell (Embedded sensor)
2: Sensor with thermowell, with thermal compound
3: Sensor with thermowell, without thermal compound
4
5
6
7
8
9
10 Minutes
±(0,3 + 0,005×t)°C
±1/3 × (0,3 + 0,005×t)°C
±1/6 × (0,3 + 0,005×t)°C
±(0,15 + 0,002×t)°C
M20
Ø4 × 20 mm
Page 2 / 14

Publicité

Table des Matières
loading

Table des Matières