SAFETY PRECAUTIONS
C
!
Do not disconnect the Dynamic Brake Unit Input wired to the DC-link side
aution
of the unit
Remove D.B.U. cover only after both devices have been shut down and
waiting 5 minutes after power is disconnected.
39-GB
Figure 3.1.1: Terminals
WARNING!
+24 V
Risk of Electric Shock
75
Dc-Link twisted wires have a
NC
maximum length of 2 meters
76
NC
The dc-link twisted wires must be
NC
disconnected at the inverter C and D
terminals before removing the cover
+24 V
or performing any maintenance or
0V24
inspection operation.
TIM
Do not perform voltage test at the
RESET
control card terminals with megger
MCMD
equipment or high voltage testers.
0V24(MCMD)
SIN
SIN
AVERTISSEMENT!
SOUT
Risque de décharge électrique.
SOUT
Les fils torsades du dc-link ont
une longueur maxi de 2 metres.
MASTER
BR
Les fils torsades du dc-link doivent
être deconnectes des connections C
OK
et D avant d'ôter le couvercle ou
AL
d'effectuer toute operation d'entretien
et de contrôle.
N'effectuer aucun test de tension
aux connections de la carte de
contrôle avec equipment megger
ou des testeurs de haute tension.
—————— Braking Unit ——————