Napoleon Vector Serie Manuel D'installation page 49

Masquer les pouces Voir aussi pour Vector Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

single-sided recessed
Ceiling
minimum framing
Ref
LV38-1
K
E
F
53 13/16" (136.7cm)
Optional - Appliance does not need to be elevated above fl oor
J
L
73" (185.4cm)
M*
*Can only be increased to 4" max by building a protrusion.
note:
The LV series requires a minimum enclosure/ceiling height, as illustrated (dimension L), measured from the bottom of
the appliance. For temperature requirements, this area must be left unobstructed. Some venting confi gurations that
require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and
combustibles.
fi nish framing - after appliance installation
L
M*
J
LV50-2
LV62
39 15/16" (101.4cm)
20 1/8" (51.1cm)
65 13/16" (167.2cm)
77 13/16" (197.6cm)
3" (76mm)
note:
Shaded components (fi nish framing) must be
non-combustible materials.
Finish framing must be built after the appliance has
been placed in its fi nal position and venting
connected.
This confi guration also requires recess
area to use non-combustible facing due
to close proximity to vent.
K
F
E
LV74
89 13/16" (228.1cm)
91" (231.1cm)
Drywall
Insulation
W415-2034 / C / 04.21.21