2 Installation with adjustment in height on the already existing base in concrete (Fig.3).
By using the plate as drilling template, drill 4 holes, and insert the Ø 10mm steel screw anchors for threaded bars.
Tighten the 4 threaded bars, M10/120mm, and anchor the screw anchors by tightening the nuts "B" to floor with the corresponding washers.
With reference to Fig. 3, position the foundation plate by means of the adjustment nuts "A". After carrying out the required regulations, position the motor
as shown in Fig.6, and lock it, as indicated in Fig.7.
3 Installation with adjustment in height on concrete base.
With reference to Fig. 4, fit the stretcher bolts on the foundation plate and provide for a hole of adequate size.
Immerse the stretcher bolts in concrete, then remove the nuts "D" and the 11x30, large band washers "R". Move them under the plate to allow for re-
gulations in height of the actuator (Fig. 5).
Carry out the regulations shown in Fig. 6 and lock the motor as indicated in Fig.7.
CAUTION: apart from the fitting modality used, carefully check that the actuator is steadily positioned and the materials are suited to the in-
tended use.

5) RACK FIXING

Iron rack, 12x30mm M4.
Position the spacers D by welding or fit them to the gate with screws at 130/150mm height from the centre line of the slot used for fitting to the base on
which the foundation plate is to be fixed.
Keep the pitch of teeth between the two parts of the rack; the joining with another piece of rack would make it easier to achieve (see Fig.8)
Secure the rack with the screws V making sure, once the actuator has been installed, that between rack and the drive gear there is always approx. 1mm
clearance (see Fig.9); to get this clearance use the slots on the rack.

6) LIMIT STOP FLASK POSITIONING (SEE FIG.10)

Open manually the gate and leave approximately of 1÷3cm, depending on gate weight, between gate and positive mechanical stop A; tighten the limit
stop flask S with the grains G to press the limit stop micro. Repeat the sequence with closing gate.

7) HOW TO INSTALL THE MAGNETS(BULL 17 OMI.S/BULL 17 OMAI.S) FIG.11

The magnets are housed in special supports (fig.11-"A"). These magnets are to be fitted to the limit switch brackets or the rack and cause the triggering
of sensors when they approach them.
Fitting onto the limit switch brackets
The bases are complete with hooking tongue allowing the fitting of the magnets to the limit switch bracket supplied with the operator, as shown in Fig.11-B.
This type of fitting allows to rapidly adjust the position of magnets. After calculating the correct distance, fix the support in the correct position by means
of a screw, so as to avert the moving of the bracket.
Fitting onto the rack
As an alternative, the supports can be fitted directly to the rack, by using the slots shown in Fig. 11-C. This fitting mode does not allow for subsequent
regulations. It is therefore advised to make some trials with temporarily fitted supports before carrying out the final fitting.
IMPORTANT: The correct distance of the magnet with respect to the sensor depends on the installation characteristics. This space cannot be preset
and must be adjusted on a trial basis.
The distances regarding the triggering of the sensor (value X) with respect to distance K of 3 and 35 mm, which are shown in Fig. 11 are only indicative.
In any case, distance K must not exceed 35 mm as a higher distance will not allow the triggering of the magnetic sensor.

8) MANUAL OPERATION (SEE FIG.12-13-14)

In the event of power failure or malfunction, to manually operate the gate proceed as follows:
- After inserting the customized key C, turn it anti-clockwise and pull the lever L.
- The geared motor is unlocked and the gate can be moved by hand.
- To return to the normal operating mode, close the lever L again and manually activate the gate until it is geared.
- Move the gate in one of the limit switches so that the next maneuver is at normal speed.

9) WIRE DIAGRAM

For the wire connections of the system and to adjust the operating modes, please refer to the Instruction Manual of the control unit.
In particular, the anti-crash device (encoder) should be adjusted according to regulations in force.
Please remember that the device should be earthed by means of the appropriate terminal.

10) CP.YAK OTI CONTROL UNIT

10.1) INPUT/OUTPUT FUNCTIONS

Terminals
Function
L-N-GND
Power supply
U-V-W
Three-phase engine
Lamp
Flashing
24 Vdc
24 Vdc
SCA
SCA
Phototest
Phototest
COM
Common
OPEN
Opens
CLOSE
Closes
P.P.
Step-step
PED
Pedestrian
STOP
Stop
PHOTO
Opening photocell
PHOTC
Closing photocell
22
Description
Power input of single-phase network.
L: Phase - N: Neutral - GND: Engine housing earth connection.
Please note that the ground must be connected as indicated in the diagram in Fig. 11.
U-V-W three-phase engine connection.
Flashing connection 230Vac 40W max or 115Vac 40W max (BULL 17 OMAI).
Power supply output accessories 24Vdc/500mA max.
Voltage free N.O. contact for open gate light 24 Vac, 0.5 A max, configurable via the SCA logic
Phototest output for verified photocells, see figure 17
Common for all control inputs.
OPEN button input (N.O. contact).
CLOSE button input (N.O. contact).
Step-step button input (N.O. contact)
Pedestrian button input (N.O. contact)
STOP button input (N.C. contact)
Input for photocell active only in the opening phase
Input for photocell active only in the closing phase