Installation instructions for wall mounting
Position wall box at a height of 1.2m - 1.5m.
Insert wires into power module, observing
correct polarity
Attach wallplate to wall box or surface
(Power module remote).
Optional spacer for surface
mounting.
4
Standard EU
Schuko Wall box
1.2–1.5m
Push power module into wallbox with mains
wiring to the rear
~
230V
mains.
The power module can be installed in a
+ – X Y
different location from the evotouch unit.
DC
Not used
Disconnect low voltage cable from wallplate
terminal block and extend the connection by
Use screwdriver
up to 10m max. using 1.0mm² cable. If smaller
with 2.5mm
size cable is used the maximum distance will
head
reduce (e.g. 5m max with 0.5mm² cable).
Observe correct polarity when connecting the
extension cable. Power Supply Cable wires are
Red (+), Black(-).
Attention: Exceeding the maximum cable
length could cause system malfunction!
Attach evotouch to
wallplate
Knock out
required holes
Caution: Isolate power supply and make safe before wiring
the unit to prevent electric shock and equipment damage.
Installation should be carried out by a competent person.
Minimum
depth
40mm
~
230V
mains.
Wires should
protrude 55 mm
Remove
protective film