Installation Of Temperature Controller - Rinnai C199i Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation of Temperature Controller

WARNING
Turn the power off. Do not attempt to connect the
temperature controller(s) with the power on.
Although the controller is a low voltage device, there
is 120 volt potential next to the temperature
controller connections inside the unit.
Do not connect the temperature controller to the
120VAC terminals provided for the optional solenoid
drain valves.
Indoor models have their controller built into the
front panel. Additional controllers can be installed.
Controller Location
The controller should be out of reach of small
children.
Avoid locations where the controller may become
hot (near an oven or radiant heater).
Avoid locations in direct sunlight. The digital
display may be difficult to read in direct sunlight.
Avoid locations where the temperature controller
could be splashed with liquids.
Do not install in locations where the controller
can be adjusted by the public.
Cable Lengths and Sizes
The cable for the temperature controller should be a
non-polarized two-core cable with a minimum gauge
of 22 AWG. The maximum cable length from each
controller to the water heater depends on the total
number of wired controllers connected to the water
heater.
Number of Wired
Maximum Cable Length for each
1
2
3 or 4 *
* Only 3 additional controllers can be wired to the
indoor water heater.
48
328 ft (100 m)
164 ft (50 m)
65 ft (20 m)
C199 Manual
Configurations
A maximum of 4 temperature controllers can be
installed for a water heater or bank of water heaters.
This includes the controller built into an indoor water
heater. Controllers can only be wired in parallel.
Controllers cannot be wired in series.
Maximum 4 Controllers
Rinnai
Water
Heater
Wire controllers in parallel
The 4 temperature controllers can consist of multiple
MC-91-2.
(MC-91-1 should not be installed on a unit that
already has an MC-91-2 connected)
If 4 MC-91-2's are installed, simultaneously press the
Priority and On/Off buttons on the fourth controller
until a beep sounds.

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

C199eReu-kbd3237ffudc-usReu-kb3237wdc-us

Table des Matières