Automatic calibration of the gate run
Warning! With single-leaf gates, connect the gearmotor to terminals M2-N2-ENC2.
The calibration procedures are the same as those described below.
Preliminary checks of the direction of movement during opening
- Release both gearmotors (see paragraph on "manual release" in the installation manual), position the gate leaves to be half-way open,
block the gearmotors again.
Warning!
For Frog J, set Dip switch n. 7 to OFF.
For A1824, set DIP switch n. 7 to ON.
Briefl y press the "OPEN MOTOR"
opening movement.
Otherwise:
1) If the gate leaves close, invert the M-N phases on either of the gearmotors;
2) If the gate leaf of the fi rst gearmotor closes, invert the M1-N1 phase.
3) If the gate leaf of the second gearmotor closes, invert the M2-N2 phase.
Process for automatic calibration of the gearmotors
- Position the gate leaves so that they are half-way open by pressing on the "OPEN MOTOR" button.
- Press the "SET UP" button for about 3 seconds.
- The gate leaf of the second gearmotor perform a closing run and an opening run, ...
...Then, the gate leaf of the the fi rst gearmotor performs the same runs.
- With gate leaves fully open, the PROG LED stays on for some seconds to show the proper automatic calibration.
If the LED fl ashes check the connections and repeat the calibration procedure.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
button. Check that both gate leaves perform the
E A
A C
7ON = A1824
7OFF = FROG J