Function Selection
E
1 ON - Automatic closing - the automatic closing timer is activated when on opening the gate leaf has reached the full open stroke.
The time is preset and adjustable, and is subject to the action of any safety devices. It does not activate after a total safety
"stop" or during a power outage;
2 ON - "Open-stop-close-stop" function with button [2-7] and remote control (with built-in radiofrequency card);
2 OFF - "open-close-inversion" function with button [2-7] and remote control (with built-in radiofrequency card);
3 ON - "Open only" function with remote control (featuring built-in radiofrequency card);
4 ON - Pre-Flashing during opening and closing - Following an opening or closing command, the flasher connected to [10-E], flashes
for 5 seconds before initiating the operation;
5 ON - Obstacle detection - When motor is idle (gate closed, open or after a total stop command), it prevents any motion if the safety
devices (e.g. photocells) detect any obstacle;
6 ON - Maintained action - the gate works by keeping the button pressed (one button [2-3] for opening, and one button [2-4] for
closing);
7 ON - Enables to the command of A1824 operators;
7 OFF - Enables to the command of FROG J operators;
8 ON - Operation of the photocells safety test - this allows the card to assess the efficiency of the safety devices (photocells) after
each opening and closing command;
9 OFF - Total stop - this function halts the gate, consequently excluding any closing cycle; press buttons or remote control to set back
in motion. Insert safety devices on 1-2]; if not used, set DIP switch to ON;
10 OFF - Reopening during closing - if the photocells detect an obstacle during gate closing, the gate motion is inverted until total
opening is reached; connect the safety device to terminals [2-CX];
NB -Dip switches 3 and 6 are used, independently, also to activate the electrolock and ram blow (page 10).