5.9. External auxiliary equipment

This is used to control the activation of the auxiliary equipment integrated in the DHW heating buffer storage tanks via outputs to
relays. They are also used to control activation of the all / nothing external auxiliary boiler. If modulating boilers are installed, it is
also used to control the temperature downstream from the boiler, so the heat pump and the boiler can function simultaneously.
The connection terminals of the SG3 outlet unit are used to manage the auxiliary boilers, so this one cannot be used.
Description
Auxiliary heating buffer storage tank equipment
DHW inter-storage tank auxiliary equipment
Auxiliary boiler

5.10. Aerothermal or hybrid source systems

These are used to control activation of the aerothermal (NETZERO AU12) and geothermal source systems. They also generate a
regulation signal for the variable speed fan of the NETZERO AU12 unit.
The connection terminals of the SG2 outlet unit are used to manage the aerothermal source units, so this one cannot be used.
Description
Aerothermal collector (NETZERO AU12)
Geothermal collector
Table 5.7. Connection terminals for aerothermal or hybrid source systems.
GEOSMART ENERGY
Signal
Digital output
Analogue input
Analogue output
Digital output
Analogue input
Analogue output
Digital output
Analogue input
Analogue output
Digital output
Table 5.5. Connection terminals for outlet units.
Signal
Digital output
Digital output
Analogue input
Analogue output
Digital output
Table 5.6. Auxiliary equipment connection terminals.
Signal
Analogue input
Analogue output
Relay digital output
Relay digital output
Relay digital output
29
Installer manual NETZERO
Type
Activation 230Vac / 2A maximum
NTC 10K 25ºC Probe
Valve regulation 0 – 10Vdc
Activation 230Vac / 2A maximum
NTC 10K 25ºC Probe
Valve regulation 0 – 10Vdc
Activation 230Vac / 2A maximum
NTC 10K 25ºC Probe
Valve regulation 0 – 10Vdc
Activation 230Vac / 2A maximum
Type
Activation 230Vac / 1A maximum
Activation 230Vac / 2A maximum
NTC 10K 25ºC Probe
Valve regulation 0 – 10Vdc
Activation 230Vac / 2A maximum
Type
NTC 10K 25ºC Probe
Regulation 0 – 10Vdc
Defrost activation
230Vac / 2A maximum
Fan activation
230Vac / 2A maximum
Activation 230Vac / 2A
maximum
Connector
DO5
AI12
AO3
DO6
AI13
AO4
DO14
AI14
AO5
DO15
Connector
DO10
DO11
AI13
AO4
DO14
Connector
AI12
AO3
DO6
DO16
DO17