Inventum BV010 Mode D'emploi page 34

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ASSEMBLY OF THE TILTING SAFEGUARD
CONNECTING THE COOKER TO THE ELECTRICAL SYSTEM
• The cooker is supplied without a connection cable and, in accordance with connection diagram A1, it is set by
default for 2 x 1 phase (230VDC). The cooker uses a so-called 5-pole Perilex plug (not included). In the meter
cupboard, the groups must each be protected with a 16 Ampere fuse at least.
• The cooker can also be connected in accordance with connection diagram A2. This may only be performed
by a certified installer.
• The socket for connecting to the electrical system must be provided with an earthing pen and may not be
located above the cooker. The socket for connecting to the electrical system must also be accessible for
the user after placement of the cooker.
• Before connecting the cooker, check that:
- the fuse and electrical system are suitable for the load of the oven,
- the electrical system is equipped with an efficient earthing system that meets the current standards
and regulations.
- the socket is easily accessible.
connection block
A1
34
English
The tilting safeguard is mounted to prevent the cooker from tilting. Thanks to
the tilting safeguard, children are prevented from climbing on the open oven
door and tilting the cooker.
B
Cooker, 850 mm high
A
A = 60 mm
B = 103 mm
Cooker, 900 mm high
A = 104 mm
B = 147 mm
connection cable
connection block
A2
connection cable

Publicité

Table des Matières
loading