Changing the Battery Type Setting
The standard setting for the onboard battery charger is
Flooded/AGM. EXCEPTION: If your machine was
ordered from NSS equipped with Crown AGM or Gel
batteries, then the charger was configured for Gel
batteries at the factory.
Configuring the Charger for Gel batteries:
1.Remove the top cover.
2.Pull the jumper off the 2-pin connector (position 1),
and then move the jumper to position 2 on only one
pin of the 2-pin connector. See photo below.
3.Reinstall the top cover.
1.The green wire outputs a battery voltage when the
charger is not plugged in to AC to provide an
Interlock function.
2.Securely fasten the black ring terminal from the
Top cover
screws
Position 1
For Wet
Cell
(Default)
(Jumper on
both pins)
charger to the negative terminal ("-", "NEG",
NEGATIVE") of the battery pack.
3.Select Charge Algorithm if battery type is other than
factory default.
Jumper
Location
Configure the Charger for Flooded/AGM batteries
1.Remove the top cover
2.Pull the jumper from the 2-pin connector, and install
the jumper at position 1 (on both pins of 2-pin
connector).
3.Reinstall the top cover.
Position 2
For Gel Cell
(Jumper on 1
Pin of 2-Pin
Connector)