Bertos G6F2BH6 Mode D'emploi page 118

Masquer les pouces Voir aussi pour G6F2BH6:
Table des Matières

Publicité

118 |
Regulating the pilot light (gas oven FG - Fig. 4.4)
The pilot light has nozzles and fixed airflow. The only thing
that has to be done is to change the nozzles according to
the type of gas, proceeding as follows:
- Unscrew the biconical pressure nut (14( and the pilot
nozzle (16(.
- Replace the pilot nozzle with an appropriate one after
checking the "BURNERS" table.
- After changing the pilot nozzle, screw down the
biconical pressure nut (14(.
Adjusting the low point control (gas oven - Fig. 5)
After having removed the contro panel, adjust the low
flame screw (36(:
- when using LPG, it should be fully screwed down;
- if natural gas is used:
1- Find the knob of the corresponding cock.
2- Turn on the burner, set the maximum temperature and
once it reaches it, turn it to the minimum.
EN
3- Adjust the minimun flow by means of the screw 36.
The flow increases by loosening the screw and
decreases by tightening it.
4- Once the flame is considered suitable for a minimum
setting, check that it corresponds to the minimum
capacity indicated in the table on burners.
5- If the power is less than the value in the table, turn the
minimum screw again and repeat the check
6- If the power is greater than the value indicated in the table,
tighten the minimun flow screw and repeat the check.
Replacement of burner nozzles of TP40 gas radiant
hotplate (Fig. 7(. To replace nozzle (1(; remove the control
panel by loosening the screws on the bottom edge.
Remove the air regulator (2( by loosening the screws.
Replace the nozzle (1( (see table on burners(.
Replacement of burner nozzels of TP80 gas radiant
hotplate (Fig. 9)
Remove the hotplate, remove the two fixing screws of
the insulating panel on the combustion chamber bottom.
Remove the air adjustment by unscrewing the fixing
screw
and replace the nozzle (see burners tables(. Reassemble
the air adjustment and reposition the insulating panel.
Adjusting the low point control (fullplate Fig. 2)
After having removed the control panel, adjust the low
flame screw (2(:
- when using LPG, it should be fully screwed down;
- for operation with methane:
1- Locate the knob of the corresponding cock.
2- Turn the burner on and turn it to the minimum output
position.
3- Adjust the minimum flow rate with screw 2. Unscrew to
increase and tighten to decrease the flow rate.
4- Once the flame judged as suitable for a minimum
setting has been obtained, check that it corresponds to
the minimum flow indicated in the table on burners.
FULLPLATE
MOD.
N°:
5- If power is lower than the table, further loosen the
Qn
minimum screw and repeat the check.
V
kW:
Hz: 50/60
6- If the power is greater than the value indicated in the
table, tighten the minimum flow screw and repeat the
check.
Replacing the pilot flame nozzle of the fullplate (Fig. 7)
The pilot flame operates with a fixed nozzle and fixed air.
To reach the pilot flame, remove the control panel as
described above and, if necessary, remove the round
central plate of the hotplate.
Use the table on burners to replace the nozzle (B( with a
suitable one, after having loosened nut (F(.
Checking the primary air of the main burner
After changing the nozzle, as described above, check that
measure H (Fig. 7-8( of the primary air adjustment is in
accordance with the data in the burner table. To adjust the
position of the clamp (2(, unscrew it and slide it.
APPLIANCE SAFETY SYSTEMS
Safety valve
A thermocouple valve stops the gas flow from reaching
the main burner in the event of the pilot flame going out.
To restore operations, repeat the directions relevant to
igniting the pilot device.
Safety thermostat (only ovens - Fig 10))
All the cookers have a manual reset safety thermostat
positioned on the control panel or behind it. When the
safety thermostat is behind the control panel, it can be
reached by removing the burner grids and tray from the
worktop.
In gas cookers the safety thermostat blocks the gas flow
if there are any serious anomalies. If it triggers, inform the
service centre.
To reset it, unscrew nut "A" and use a narrow screwdriver to
press firmly on the reset button.
MAINTENANCE
Attention!
Before effecting any maintenance or repair operation,
disconnect the appliance from the gas or electric
power supply.
The following maintenance programme should be carried
out at least once a year:
- Check that all the safety and setting devices are
working properly;
- Check that the burners are working properly with
regard to:
• ignition
• combustion safety;
- Check the functions of the appliance as described in
paragraph "Checking the functions".
Whenever the gas ring burners need cleaning, proceed
as follows:
- remove the grids, the burner caps and the burners.
IPX2

Publicité

Table des Matières
loading

Table des Matières