England's Stove Works 25-EP Mode D'emploi page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FIREPLACE INSERT INSTALLATION
Venting Introduction
This pellet stove operates on a negative draft system, which pulls combustion
air through the burn pot and pushes the exhaust air to the vent pipe and out of the
building. This unit must be installed in accordance with the following detailed
descriptions of venting techniques; not installing the stove in accordance with the
details listed here can result in poor stove performance, property damage, bodily
injury or death. England's Stove Works is not responsible for any damage incurred
due to a poor or unsafe installation.
If questions arise pertaining to the safe installation of the stove, our Technical
Support line (800-245-6489) is available. Contact your local code official to be
certain your installation meets local and national fire codes and if you're uncertain
about how to safely install the stove, we recommend contacting a local NFI certified
installer to perform the installation.
Venting Guidelines
 ALWAYS install vent pipe in strict adherence with the instructions and
clearances included with your venting system.
 DO NOT connect this pellet stove to a chimney flue which also serves another
appliance.
 DO NOT install a flue pipe damper or any other restrictive device in the
exhaust venting system of this unit.
 ONLY use chimney liners listed for pellet appliance venting; do not use
galvanized or B-Vent pipe.
 INSTALL a block-off plate in the throat of the fireplace opening.
 SEAL each joint of pellet vent with high temperature silicone (Part # AC-
RTV3) to prevent smoke spillage into the home.
 AVOID excessive horizontal runs and elbows, as both will reduce the draft of
the venting system and will result in poor stove performance.
 INCLUDE as much vertical pipe as possible to prevent smoke from the unit
from entering your home in the event of a power outage.
 INSPECT your venting system often to be certain it is clear of fly-ash and
other restrictions.
 CLEAN your venting system as detailed in the maintenance section of this
manual.
WARNING: Venting system surfaces get HOT, and can cause burns if
touched. Noncombustible shielding or guards may be required.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
21