Surface Mounting The Light; Wiring The Light - Federal Signal Commander 371LED-120 Manuel D'installation Et D'entretien

Feu tournant
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

entrance in bottom of light. For Type 4X/IP66 applications,
the hub or connector must be suitably rated (Myers
STTTB-2 or T&B
5. Set the light on the gasket and attach it to the mounting
surface with the provided 1/4-inch screws and washers.
6. For information on making the electrical connections, see
below.

Wiring the Light

SHOCK HAZARD
To avoid electrical shock hazards, do not connect wires while
power is applied.
The Model 371LED comes assembled from the factory with two
color-coded leads for wiring to a junction box. If desired, the
factory leads can be removed and the supply connections can be
directly made to the terminal block located on the bottom of the
light base as described below
1. Disassemble the light (Figure 2 on page 11):
a) Remove the dome assembly by grasping the die-cast ring
attached to the dome and turning it counter-clockwise.
b) Remove three #10 Phillips screws that secure the LED /
motor module to the housing.
c) Remove the LED / motor module.
d) If preferred, remove the factory-supplied leads from the
terminal block.
Installation and Maintenance Instructions
®
H100-TB hubs are recommended.)
Model 371LED-120 Rotating Light
®
9

Publicité

Table des Matières
loading

Table des Matières