Installation Procedure

Countertop Requirements

9
WARNING
To reduce the risk of ignition of surrounding
combustible materials, install at least 12" (300 mm)
from both sidewalls and at least 4" (102 mm) from
the rear wall.
The countertop must be level and horizontal. The stability
of the countertop must be maintained after the cut-out
has been made.

Technical Data

Total connected load electric
Total connected load gas
(natural gas)
Total connected load gas
(propane gas)
10
10 W
59,800 BTU/h
(17.5 kW)
58,000 BTU/h
(17.0 kW)
Installation Procedure
P repare Installation Space
I n s t a l l a t i o n P r o c e d u r e
T he kitchen unit must be heat-resistant to at least 200° F
P r e p a r e I n s t a l l a t i o n S p a c e
(90°C). The stability of the unit must be maintained after
producing the cut-out.
Create the cut-out in the countertop for one or several
Vario appliances according to the installation diagram.
The angle of the cut surface to the countertop must be
90°.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat-resistant manner.
Some solid surface countertops require special
installations. For example, heat reflective tape and
rounded corners may be necessary. Contact the
countertop manufacturer for instructions specific to your
countertop.
Observe minimum distance between appliance underside
and furniture parts of
3
/
8
To improve flame stability, we recommend installing an
intermediate floor underneath the appliance in the
installation cabinet.

Install Appliance

9
WARNING
Before you plug in an electrical cord or turn on
power supply, make sure all controls are in the OFF
position.
Place the appliance evenly in the cut-out. Push it down
firmly into the cut-out.
Note: The appliance must sit securely in the cut-out and
must not be able to move around (e.g. during cleaning). If
the width of the cut-out is at the upper tolerance limit,
secure battens to the sides of the cut-out if necessary.
" (10 mm).