TROUBLESHOOTING
Use the inspections in the table below if the tool does not operate normally. If this does not remedy the problem, consult your
dealer or the HiKOKI Authorized Service Center.
1. Power tool
Symptom
Does not operate.
The speed does not
change.
Goes on, but soon
stops.
Strong vibrations.
The brake fails to engage
1-3 seconds after the
lever is released.
Possible cause
The rechargeable battery is depleted.
The rechargeable battery has not been
properly installed.
The power has not been turned on.
The main pipe is not fully extended
(The red light blinks rapidly) (CG36DTA,
CG36DTA (L) only)
The lock lever was not pressed when the
lever was pulled back.
The tool pulls in large volumes of grass that
are caught between the cover and the nylon
head, the tool is overloaded.
The rechargeable battery power is low.
The rechargeable battery power is low.
The rechargeable battery is overheated.
The locking lever is not locked, causing the
main pipe to shorten up during work.
(The red light blinks rapidly) (CG36DTA,
CG36DTA (L) only)
The loop handle is not properly attached to
the main pipe.
The cover is not been properly attached to
the main pipe.
This may be due to a malfunction of the tool.
○ Identify safety measures to protect the operator that are
based on an estimation of exposure in the actual conditions
of use (taking account of all parts of the operating cycle
such as the times when the tool is switched off and when it
is running idle in addition to the trigger time).
Charge the rechargeable battery.
Remove the rechargeable battery from the
battery compartment in the tool and check for
and remove any foreign matter. Also check
the battery electrodes for soiling, water or
other foreign matter. Use a cotton swab for
cleaning. Make sure that the rechargeable
battery is pressed in until it clicks into place.
Press the power button on the housing to
start the tool. This tool comes with an auto
power off function. The power is automatically
turned off if nobody pulls the lever during a
one minute period after power on. To turn
the tool on again, press the power button a
second time.
Pressing the power button a second time
turns the power off .
To prevent accidents due to malfunction,
the tool is designed so that the motor will
not operate unless the main pipe is fully
extended.
Extend the main pipe fully until it clicks.
To prevent accidents from incorrect operation,
the lock lever must be pressed while the lever
is pulled back to start the motor.
Hold the handle from above and press the
lock lever while pulling the handle.
This is the eff ect of a function that protects the
rechargeable battery by turning off the motor
when the tool is exposed to an excessive
load. Turn off the tool and remove the cause
of the overload. Press the power button once
again to continue operation.
Charge the rechargeable battery.
Charge the rechargeable battery.
Stop using the rechargeable battery, remove it
from the tool and let it cool in a well-ventilated
location not exposed to sunlight.
Lock the locking lever.
Secure properly.
Secure properly.
Contact the store where you purchased
the tool or your nearest HiKOKI Authorized
Service Center.
18
Remedy

Publicité