2.PRINTER SETUP
2.10 Threshold Setting
(Cont.)
NOTE:
The threshold can be manually
set as follows:
Manually set threshold =
Peak voltage – Threshold fine
adjustment value
e.g.) When Peak=3.5V and
Fine adjustment value=1.0V,
the threshold will be set to
2.5V.
(6) To return to the previous display, press the [LEFT].
To set a fine adjustment value, press the [RIGHT]. The threshold
fine adjustment screen in ADJUST SET menu appears.
Set a value and press the [ENTER], [PAUSE] or [CANCEL].
(7) The result after manually setting the threshold is displayed.
To set a fine adjustment value, press the [LEFT].
To return to the sensor selection screen, press the [FEED].
To terminate the threshold setting, press the [ENTER]. The printer is
placed in Pause state.
(8) After the threshold is properly set, exit the threshold setting mode
and place the printer in the user system mode to set the Threshold
select parameter to Manual Set for the applicable sensor.
For details, refer to Section 2.6.2.2 Software Set.
PAUSE
[RESTART]
ONLINE
Hold down [MODE]
User System Mode
<2>PARAMETER SET
(9) Return to the User System Mode menu by pressing the [MODE].
Choose <1>RESET and press the [ENTER] to reboot the printer.
(10) When the printer is placed in the online mode, press the [FEED] to
feed the media.
If a paper jam occurs or the media does not stop at the print start
position, retry the threshold setting.
E2-60
Software Set
THRESHOLD SELECT
REFLECT
▪ MANUAL SET
▪ COMMAND SET
TRANS.
▪ MANUAL SET
▪ COMMAND SET
2.10 Threshold Setting