6. Installation preparation

 Make sure there is a level surface at the
installation location.
 Fit wall sleeve suitable for nominal
diameter in outside wall.
 Fit empty ducting enclosed [3] (for
connection cable) in outside wall.
Note position of connection cable in
i
rear housing wall. For spacing, refer to
Table 1, position "D".
7. Installation
The shutter is supplied fully assembled. Do
not disassemble shutter.
 Align shutter and mark position of 4 holes.
For spacing, refer to Table 1, position "C".
 Drill 4 mounting holes, insert dowels.
Suitable mounting material is to be
supplied by the customer.
 Press fly screen [4] onto journals of rear
shutter wall.
 Attach cable [2] to outer wall through empty
ducting [3].
Shutter function!
NOTICE
 Ensure that the cable [2] is
taut when guided out of the
shutter and that this does not
jam the inner slide valve. If
this is not done, the shutter
function is not guaranteed.
 Securely screw shutter to wall with
4 screws. Suitable mounting material is
to be supplied by the customer.

7.1 Electrical connection

Danger to life from electric
shock
 Switch the mains fuse off.
DANGER
 Position a warning notice to
avoid the unit being
accidentally switched back on.
 Carry out electrical connection according to
wiring diagrams on page 14 or 15.
8
i
Notes
● Always note the relevant specifications for
electrical installations and when fitting
equipment. In Germany observe DIN
VDE 0100 and the corresponding parts
in particular.
● The connection cable between the shutter
and fan terminal box must be permanently
laid.
● Only connect shutter in parallel to fan.
● Do not connect shutter to a controlled
source of voltage.
7.2 Start-up
 Check that the technical data has been
adhered to, by reference to the rating plate.
 Ensure that the air can flow unhindered.
 Carry out a function test. Check that the
closure and opening function is working
correctly.
8. Maintenance
The shutter is maintenance-free.

9. Fault rectification

● Call on the services of a trained
electrician any time there is a fault.
● Repairs should only be carried out by a
trained electrician.
Danger to life from electric
shock
 Switch off mains fuse before
DANGER
repairs.
Fault
Shutter not
opening or
closing
Fig. 2: Fault rectification
Countermeasure
Check that the mains fuse
is switched on.