Operating Test; Maintenance, Emergency Action & Cleaning; Protection Of The Environment - Comunello AIRWIN A45 230VAC Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5.4 Operating test

Press the control button and close the window, checking that:
a. The window is completely closed. If it is not, check that the gap between the window and the frame is bigger
than or equal to 0 mm. If necessary, insert spacers so as to obtain the correct gap.
b. The rack is perfectly vertical to the window frame. If necessary adjust the fixing bracket by using the screws
and slots.
Having reached the correct closing position, press the control button and open the window in order to check
that the actuator runs freely over the full travel set up.
Having achieved the required opening run, press the control button again to close the window. Once the window
has completely closed, check that the screws, supports and fixings are tightened correctly, and that the seals
are sufficiently compressed.
Installation completed
6. MAINTENANCE, EMERGENCY ACTION &
CLEANING
If it becomes necessary to manually disconnect the window from the actuator due to: a power failure, mechanical
breakdown, maintenance, or cleaning the exterior of the window, follow the step sequence described on Page 9 in
reverse order.
BEWARE OF THE DANGER of the window falling; as the window is free to fall, as it is no longer held up by the spindle.
Once the maintenance or cleaning operations have been completed, repeat the sequence described on Page 9.

7. PROTECTION OF THE ENVIRONMENT

Some parts inside the actuator are not recyclable (plastic materials and electronic parts) and cannot be
considered normal refuse. They must be disposed of correctly. In case of doubt, consult the relevant refuse
disposal body.
15

Publicité

Table des Matières
loading

Table des Matières