5. INSTALLATION

46.5
38
10 10
25
53.5

5.1 Installation sequence

Check that the force required to open/close it (calculated according to the table under Point 4.2) is less than
or equal to that shown in the TECHNICAL DATA table.
Try manually the window opening, checking for and if necessary eliminating any sticking points that could
cause a malfunction.
Manually test the maximum opening of the window, checking that it is greater than the travel set by the
actuator.
CAUTION
If the application is on bottom-hung windows, there is a danger of potential injury resulting from the
window accidentally falling.
It is OBLIGATORY to fit limiting arms (of the Series 1276 type), or an alternative safety system, of a
suitable size to prevent the window from accidentally falling down.
Top-hung window: Overall dimensions and fixing holes
L=180/336 - 230/336 - 350/646 - 750/846 - 1000/1096
333
32
57
7

Publicité