3.2 Datas

Type
Nominal performance
Heating capacity (m
-under favourable
-less favourable
-not favourable heating circumstances
according to 18893/TAB2 DIN standard
Flue gas values:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at performance:
dust (relating to 13% O²)
CO (relating to 13% O²)
efficiency
All information provided by the exhaust gas values are based on the EN 13240 under stationary
laboratory conditions
We reserve the right to make changes which relate to technical advances and / or to an improve-
ment in quality. We accept no liability for printing errors and changes which occur after printing.
Haus – und Küchentechnik GmbH
Adelperost. 86
D – 85737 Ismaning
Telefon +49 (0)89 32084-0
Telefax +49 (0)89 32084-294
www.wamsler.eu
3
)
fuel:
37
TYP108 80 Vision
8 kW
182
105
71
wood / brown coal
10,2 / 11,5 g/s
250 ˚C
12 Pa
< 40 mg/m³
1108 / 748 mg/m³
0,09 / 0,06%
82,0 / 76,8 %