Notes on setting the key removal positions:
Setting the 1. key removal position:
• Bars are locked, key is removed. Loosen stop screw 6 according to fig. 8, push the stop
slide in the direction of the arrow until it stops, tighten stop screw.
Caution! Do not overwind.
Setting the 2. key removal position:
• Lock the bar with two key rotations and remove the key.
Loosen stop screw 7, push the stop slide in the direction of the arrow until it stops, tighten
stop screw.
Caution! Do not overwind.
When locking with one turn:
• Lock the bar with two key rotations. Unscrew stop screw 6., hold stop slide, close back
the bar with one turn, remove the key. Push the stop slide in the direction of the arrow
until it stops, tighten stop screw.
Caution! Do not overwind.
Fig. 8
3.
2. – one tooth back
7.
5.
6.
4.
1.
VI. Fitting instructions for doors that open inwards
For a door opening outwards, please continue to read about special accessory PA1018
in the fitting manual.
Before fitting, please check the door setting and properly set if required.
Please check that the PR2600 fits onto the door panel for one-turn locked door bars
before carrying out the fitting steps described below. Perhaps use PWA2700 in the
narrow niche area (fig. 24 - 26).
If the PR2600 can or must be used for one-turn locking, the key removal position must be
set before fitting the lock body (see Chapter V, 8.).
40
Fitting the lock body
1. Set and mark the position of the lock body on the door panel (Fig. 3+4).
2. Mark a hole Ø 51–55 mm in the middle accordingly Fig. 9 and drill with a milling cutter/
hole saw from both sides.
Before fitting the lock body, remove the cover hood corresponding to Fig. 10.
Fig. 9
½
½
Ø 51–55 mm
3. Mount the lock body, attach the escutcheon at door exterior (Fig. 11).
4. Position lock body corresponding to Fig. 12.
Pre-drill the position of the mounting screws (wood Ø 3,0 mm/metal Ø 3,5 mm)
and tighten the lock body with screws Ø 4,2 x 22 mm.
Note: With cavity doors, pre-drill Ø 6mm, use supplied bridging cartridge and tighten
with Ø 4 x 35 mm screws corresponding to Fig. 13.
Caution! Do not overwind.
Fig. 11
Fig. 13
Ø 4 x 35 mm
Fig. 10
Fig. 12