1, The regulator shall comply with the standard EN16129;
For category I3+, the appliance shall use the butane 30mbar regulator (reduce pressure:28-30mbar) or the
propane 37mbar regulator (reduced pressure: 37mbar).
For category I3B/P(30), the appliance shall use the LPG 30mabar regulator(reduced pressure:28-30mbar).
For category I3B/P(50), the appliance shall use the LPG 50mabar regulator (reduced pressure:50mbar).
2, The hose shall comply with the standard EN 16436 and the length of the hose should not exceed 1.5m.
3, The minimum distance from non protected combustible materials shall be 2m.
4, To change the gas cylinder in a amply ventilated area, away from any ignition source (candle, cigarettes,
other flame producing appliances, ...).
5, To check that the regulator seal is correctly fitted and able to fulfil its function.
6, Do not obstruct the ventilation holes of the cylinder housing.
7, Close the gas supply at the valve of the gas cylinder or the regulator after use.
8, In the event of gas leakage, the appliance shall not be used or if alight, the gas supply shall be shut off
and the appliance shall be investigated and rectified before it is used again.
9, Check the tubing or the flexible hose (at least once per month and each time the cylinder is changed).
If it shows signs of cracking, splitting or other deterioration it shall be exchanged for new hose of the
same length and of the equivalent quality;
10, Read the instructions before installation and use.
11, This appliance must be installed and the gas cylinder stored in accordance with the regulations in force.
12, Do not obstruct the ventilation holes of the cylinder housing.
13, Do not move the appliance when in operation.
14, Shut off the valve at the gas cylinder or the regulator before moving the appliance.
15, The tubing or the flexible hose must be changed within the prescribed intervals.
16, Use only the type of gas and the type of cylinder specified by the manufacturer.
17, In case of violent wind particular attention must be taken against tilting of the appliance,
18, Keep the instructions for future reference.
19, Do not connect the gas cylinder directly to the appliance without regulator.
20, The tubing or the flexible hose must be changed within the prescribed intervals.
21, Use only the type of gas and the type of cylinder specified in these instructions.