Leakage Test; Lighting Instructions; After Use And Storage - Italkero ETNA Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Gas connections on the heater are leak tested at the factory prior to shipment. A complete leakage test should
be performed at the installation due to possible mishandling in shipment or excessive pressure being applied to
the heater.
Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied with
a spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
The heater must be checked with a full cylinder.
Make sure the safety control valve is in the 'OFF' position.
Turn the gas supply from the cylinder ON.
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on and
recheck.
Never do leak test while smoking.
Open the cabinet door and put the gas cylinder into the cabinet.
Make sure to turn the control knob clockwise to "OFF" position.
Connect the regulator to the gas bottle.
Turn the gas supply "ON" at the cylinder. Check with the use of soapy water for any gas leakage between the
cylinder and the regulator
Push down the control knob and keep pressing whilst turning anti-clockwise to the "Ignition" position (a
click will be heard), this will light the pilot.
If the click is not heard repeat this process. Note that when first connecting heater to the gas cylinder there
will be air in the gas hose or the rest of the system. Keep pressing the control valve knob for about 1 minute
to purge the air and allow gas into system.
Once the pilot burner is lit, keep the control knob pressed for 5 seconds then release it.
If the burner does not stay alight, repeat the above steps again.
Adjust the heat setting by turning the control knob to the 'High' or 'Low' position.
To shut down the heater turn the gas cylinder valve or regulator switch to the 'OFF' position and then turn
the control valve knob on the appliance clockwise to the 'OFF' position.
WARNING:
If the burner fails to ignite, turn the control valve knob 'OFF' (clockwise) and turn the gas cylinder valve 'OFF'.
Wait for five minutes before attempting to relight with ignition sequence.
Turn the control knob on the appliance clockwise to the 'OFF' position.
Turn the gas supply off at the cylinder.
Do not leave the area until flames have fully extinguished.
Children must not be left unattended straight after use as the appliance will still be hot for some time.
Check gas valve for tightness and damage. If damage is suspected this must be changed by a qualified
technician.
Always store gas cylinders in well ventilated areas.
Once heater has cooled down it can be moved to alternative location such as garage of shed.
Once heater has cooled down it is safe to use rain cover for protection.

LEAKAGE TEST

LIGHTING INSTRUCTIONS

AFTER USE & STORAGE