Faults / Solutions; Start-Up Problems; Possible Causes - Riello Gulliver RG3 393T1 Manuel D'entretien

Brûleur fioul domestique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SIGNAL
7 pulses

8 pulses

ATTENTION
To reset the control box after the diagnostics display, press the lockout-reset button.
6.

FAULTS / SOLUTIONS

Below is a list of some of the causes and possible solutions to a series of problems that might be encountered
and could cause a failure to start or irregular burner operation.
A fault usually makes the lock-out lamp light which is situated inside the reset button of the control box (3, fig.
1, page 2).
When lock out lamp lights the burner will attempt to light only after pushing the reset button. After this if the
burner functions correctly, the lock-out can be attributed to a temporary fault.
However, if lockout continues, you must determine the cause of the problem and take the action illustrated in the
solution column in the tables below.
6.1

START-UP PROBLEMS

FAULT
The burner doesn't
start when the limit
thermostat closes.
The burner goes in
safety lock-out
before or during the
pre-purge phase.
Burner runs normal-
ly in the prepurge
and
ignition
cycle
and locks out after 5
seconds ca.
3280
Loss of flame during operations:
– poor burner regulation (insufficient gas);
– oil valve faulty or dirty;
– flame detector faulty or dirty.
Check and monitor oil heater (if fitted):
– check the correct position of the bridge socket "P".

POSSIBLE CAUSES

Lack of electrical supply.
Bridge socket "P" missing or discon-
nected.
The connections in the control box
are wrongly inserted.
The flame detector sees strange light.
The flame detector is dirty.
The flame detector is defective
Flame moves away or fails.
PROBABLE CAUSE
Check presence of voltage in the
L1 - N clamps of the 7 pin plug.
Check the conditions of the fuses.
Check that safety thermostat is not
lock out.
Connect it up properly.
Check and connect completely all the
plugs.
Eliminate the light.
Clear it.
Change it.
Check pressure and output of the fuel.
Check air output.
Change nozzle.
Check the coil of solenoid valve.
14 GB
SOLUTION

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

3739354

Table des Matières