Walter Surface Technologies BIO-CIRCLE COMPACT-S 350 Manuel De L'utilisateur page 14

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting Guide
3.
The cleaning pump intake may be clogged. Unplug the unit.
Disconnect the rubber hose from the elbow fitting at the back of the
machine. Lift the RMU (H) out of the fluid, unscrew the pump intake
Cleaning PumP stoPs
The built-in float switch will cut power to the cleaning pump when solution
level has reached the minimum of approx. 90 liters/23.7 gal.
Top-off tank to the proper working level of at least 100 liters/26.5 gal.
with bio-Circle aero™ (No. 55-A 207, 20 liters/5.3 gal. 55-A 208,
208 liters/55 gal.), bio-Circle l™ (No. 55-A 007, 20 liters/5.3 gal. or
55-A 008, 208 liters/55 gal.) or bio-Circle ultra™ (No. 55-A 107,
20 liters/5.3 gal. or 55-A 108, 208 liters/55 gal.).
the Cleaning fluid is Cold
1.
Confirm the unit has been on for several hours
2.
Check that the fluid level is topped up
3.
Ensure, the float can move freely.
If the fluid is still not being heated, please contact the bio-CirCle
technical support line. See page 20 for contact information.
aeration has stoPPed
Aeration has stopped but air pump is still running.
1.
Inspect that the air hoses are not pinched along their length.
2.
Inspect that both air diffusers attached to the end of the air hose next
to the pump are clean and functioning; if not replace them immediately,
see the "ACCESSORIES" section.
14
Compact-S Model 350 - Parts Cleaning System
(...continued)
®

Publicité

Table des Matières
loading

Table des Matières