USER MANUAL
If the indicated pressure is not 6 bars (85 p.s.i.), check the pressure at the air source (compressor). Then, if pressure is correct at
the air source, it means the regulator of the machine needs fine tuning. Perform the following procedure to adjust it (Figure 2-9
and Figure 2-10)
Allen key N.3
Unscrew
both
screws
of
the
drawer panel with a
3mm Allen key.
Then
open
the
drawer
to
have
access to the air
pressure
regulator
knob.
Pull
up
pressure
knob and turn it
(clockwise = more
pressure) until the
needle of the air
pressure
reaches
(85p.s.i.).
Figure 2-9
the
air
regulator
gauge
6
bars
MACH 4 UNI
Figure 2-10
12